Tingling in the water or sparks? Get everyone out, power off at the breaker if safe & call 911 if anyone is hurt.

Brands & error codes

Raypak pool heater error codes

Raypak's digital gas heaters (models 206A, 266A, 336A and 406A) spell out what's wrong in words on the display. These meanings come from Raypak's own installation and operation manual. Older or other Raypak models can show different messages, so check your manual.

Last updated · Reviewed by the Pool Helpline tech team

If you smell gas, stop

Smell gas? Raypak's manual says: don't try to light any appliance, don't touch any electrical switch or use any phone in your building, and call your gas supplier right away from a neighbor's phone. If you can't reach them, call the fire department. Raypak says installation and service must be done by a qualified installer, service agency or the gas supplier. Smoke or fire: call 911.
Power off first. Turn the pump (and heater) off and switch off the breaker before you open the pump lid, the filter or any equipment panel. Wiring, breakers, GFCIs and pool lights are jobs for a licensed electrician. Never go in the water if you suspect an electrical problem.

Normal status messages

Not every message is a problem. With no active faults, Raypak lists three normal messages:

DisplayWhat it means
HeatingThe heater is being asked for heat and the flame is lit.
SparkThe igniter is sparking to light the heater.
No DemandThe water has reached the set temperature, so the heater isn't being asked for heat.

Messages when it's calling for heat

Raypak says these show only while there's a demand for heat.

DisplayWhat it means
Water Sw OpenThe water pressure switch is open. The heater isn't seeing enough water flow from the pump, so it won't fire.
Vent/Field Sw #1The vent spill switch (or a field-added switch) is open.
Hi Limit 1 is open / Hi Limit 2 is openA high-temperature limit switch opened. On ASME units only, it's a manual reset: press MODE.
Rollout Sw OpenThe flame rollout switch opened. This is a combustion safety switch: leave it off and call a qualified tech.
Flow/Field SW #2A field-supplied flow switch (or other field switch) is open.
Ignition Lockout / Ignition FailureThe pilot didn't light in time ("No pilot sensed"), or the pilot was lost while lighting the main burner ("Main Ign Failure").
Ign 60 min DelayThe pilot was lost 4 times while lighting the main burner. The heater locks out for 60 minutes, then tries again.

Fault messages

DisplayWhat it means
Sensor FailureThe temperature sensors disagree by more than 2°F.
Sensor Open / Sensor ShortA temperature sensor has failed open or shorted.
Flame w/o CFHThe board senses a flame when the gas valves should be shut. Turn the heater off and call a qualified tech.
PV Output FaultThe pilot gas valve output isn't doing what the board told it to.
LoNox Tab FaultThe board sees a Lo NOx signal on a heater that isn't a Lo NOx model.
Internal Fault / EEPROM FaultA control board or memory fault.
Clock/Fireman SwThe time clock or fireman's switch circuit is open.
Low TempWater temperature is below 36°F.

Two safe first checks

  1. Flow first. For Water Sw Open, and for a high limit that trips, make sure the pool pump is running and the filter and baskets are clean, and run a variable-speed pump faster while you test. Raypak says its water pressure switch lets the heater run only when the filter pump is on, and that its pressure switch should be set by a qualified service person, so don't adjust or bypass it.
  2. Pump run time. Raypak's fix for high limit events is to confirm the circulation pump runs during the whole heating cycle, and that the pump shuts off at least 5 minutes after the heating cycle ends. Otherwise leftover heat can trip a high limit. If your timer or automation shuts the pump off with the heater, that's worth a look.

If the message comes back with good flow, or you see Rollout Sw Open, Vent/Field Sw #1, an ignition, sensor or board message, stop there. Those involve gas, venting, combustion or control parts, and Raypak says they're for a qualified service tech.

Get a tech on video

On a video call a tech can read the exact message, look at the rating plate, the plumbing and the pump settings, and tell you whether it's flow, a timer setting, or a part such as a pressure switch, sensor or igniter. You'll know what you need before anyone orders a part. For other brands, see pool heater won't fire.

Common questions

What does Water Sw Open mean on a Raypak heater?

The water pressure switch is open, so the heater isn't seeing enough water flow from the pump and won't fire. Check that the pump is running and the filter and baskets are clean. Raypak says the pressure switch should be adjusted only by a qualified service person.

Why does my Raypak heater say Hi Limit is open?

A high-temperature limit switch opened. Raypak says to confirm the pump runs during the whole heating cycle and keeps running at least 5 minutes after heating ends, so leftover heat doesn't trip the limit. On ASME units it's a manual reset with the MODE button. If it keeps happening, contact a qualified tech.

What does Ign 60 min Delay mean on a Raypak?

The pilot flame was lost 4 times while the heater was trying to light the main burner, so it locks out for 60 minutes before retrying. Make sure the gas supply is on. If it repeats, call a qualified tech: ignition and gas parts aren't owner repairs.

What does Rollout Sw Open mean?

The flame rollout switch opened. It's a combustion safety switch. Leave the heater off and have a qualified tech check it.